Dieser Inhalt ist derzeit in seiner Originalsprache verfügbar.
Growlink Level Sensor (for Batch TankLINK)
Modell / Artikelnummer: GL-LINK-LEVEL
Reading Tank Level with the Growlink Batch TankLINK Level Sensor
- Sensor Type
- Float / serpentine pontoon
- Output Signal
- 4–20mA analog
- Connector
- Molex (1× 4–20mA input on controller)
- Compatible Controller
- Growlink Batch TankLINK (alongside pH, EC, Temp inputs)
Nur zum Vergleich. Fordern Sie Ihren aktuellen Großhandelspreis, die Verfügbarkeit und die Lieferbedingungen an.
Keine Zahlung erforderlich. Ein Gespräch über Ihre Bedürfnisse.
Noch ein paar weitere Informationen zu diesem Produkt
Reading Tank Level with the Growlink Batch TankLINK Level Sensor
Product details
- The Growlink Batch TankLINK Level Sensor floats a serpentine pontoon directly in the nutrient tank.
- The pontoon's shape lets the assembly drop through narrow tank openings without disassembly.
- The transducer translates that movement into a 4–20mA signal.
- A Molex connector carries the signal to the controller's level input.
- That feed drives the TankLINK's refill logic and overfill alarms.
- The controller can call a fill pump on or trip an alert before the tank crosses either threshold.
- Wiring the TankLINK Level Sensor into the Same Tank as pH, EC, and Temp
- Most growers position this TankLINK level sensor in the same tank that already holds the pH, EC, and temperature probes.
- A single Batch TankLINK runs all four inputs from one board.
- The 4–20mA output is the standard analog type the controller's level input expects.
- The nutrient tank level sensor wires in with no protocol conversion.
- Plug-and-play installation keeps a sensor swap to a few minutes during tank teardown.
- Lift the pontoon, unplug the Molex, drop in the new unit, and the controller picks the reading back up at the next sample cycle.
- Tank cleaning between runs is the most common time to inspect the pontoon for scale buildup.
- A wipe with a soft cloth keeps the batch tank level sensor reading honest across the next harvest cycle.
- The continuous 4–20mA reading also pairs with the controller's logged history for season-over-season fill-rate analysis.
- That helps spot a slow leak or a clogged refill solenoid before the next crop suffers a dry-tank hour.
- 4–20mA Analog Output: Standard signal type wired straight into the Batch TankLINK controller's level input.
- Molex Connector Wiring: Plug-and-play swap during teardown — unplug, lift, replace, plug back in.
- Automated Refill + Overfill Logic: Feeds the controller's level thresholds for pump triggers and alert calls before the tank crosses either.
- Continuous Level Tracking: Real-time reading across the full tank stroke, not just point-level high/low switches.
- Technical Specifications
Spezifikationen
- Sensor Type
- Float / serpentine pontoon
- Output Signal
- 4–20mA analog
- Connector
- Molex (1× 4–20mA input on controller)
- Compatible Controller
- Growlink Batch TankLINK (alongside pH, EC, Temp inputs)
- Molex Connector Wiring
- Plug-and-play swap during teardown — unplug, lift, replace, plug back in.
Lass es uns für dein Projekt zum Laufen bringen
Bitte geben Sie in Ihrer Anfrage die gewünschte Menge, den Lieferort, die Anbaufläche sowie eventuelle Spannungs- oder Steckeranforderungen an. Spezifikationen, Verfügbarkeit, Versand- und Garantiebedingungen werden in Ihrem schriftlichen Angebot bestätigt.
Referenzumrechnung unter Verwendung des gespeicherten Wechselkurses vom 15.11.2026. Die umgerechneten Beträge stellen kein Angebot dar.
Mehr Möglichkeiten für Ihren Raum
Fragen und Diskussion
Haben Sie eine Frage oder möchten Sie etwas Nützliches teilen? Starten Sie das Gespräch.